Because One Collision Is One Too Many

The only ISO 21815-compliant system that actively intervenes to prevent run-overs and collisions on surface mines. Detection is not enough – HVB+ commands the machine to a halt.

Proven Level 9 Prevention

Mine-Hardened Reliability

SmartMine IoT Connected

Features

ISO 21815 Active Intervention

Automatically slows or fully stops the vehicle on critical-zone breach – the only true Level 9 solution.

Dynamic Speed-Based Zones

Detection zones shrink at low speed for precision and enlarge at high speed to ensure all detections are acted upon in due time.

360° Directional Accuracy <0.5 m

Four quadrant 2.4 GHz TOF units deliver precise threat direction with sub-meter accuracy.

HMI+ Tri-Colour Interface

Intuitive LED arcs and directional display instantly guide the operator to the threat location.

Full Event Logging & GPS

Every alarm and intervention recorded with position, speed, time, and direction for proactive incident investigations.

SmartMine Cloud Dashboard

Real-time fleet-wide visibility of near-misses and interventions from any GSM activated device.

Seamless SCAS underground cross compatibility

Integrates directly with existing Schauenburg proximity systems for phased rollout.

Operators stay alert, workers stay safe,

and management finally has irrefutable data. HVB+ turns every shift into a zero-incident shift.

Engineering Features

2.4 GHz chirp-spread-spectrum time-of-flight ranging

Direct CAN/J1939 machine intervention (slowdown or full stop)

Four quadrant-mounted ranging units for true 360° coverage

IP67-rated components, ISO 7637-2 compliant power system

Operating temperature
–20 °C to +70 °

Configurable warning, danger, and critical zones per vehicle type

Use Cases

Haul Truck & Light Vehicle Interaction

Prevents high-speed rear-end or side-swipe collisions with bakkies and service vehicles.

Enlarges critical zone during precise dumping or parking to protect ground workers.

Active intervention works 24/7 even when operator attention is reduced.

Directional detection eliminates collisions at pit ramps and blind corners.

Technical Specifications

Specification ParameterValue / Unit
Failure DetectionBIT – Built in Test with system of error codes Start-up sequence lights up all indicators on the HMI during system pre-use checks
Operating Voltage/Protection Operating Current11V – 30V 707mA (Max) (at 13V)
Peer-Peer Communication Back-to-Base CommunicationISM band Radio UHF (868MHz) GSM
Detection IdentificationSystem distinguishes between different types of large vehicles, small vehicles, hazards and pedestrians
Driver IdentificationBuilt in Time-of-flight technology for driver exclusion
Physical Dimensions of HVB+ VMU271.6 mm x 141.6 mm x 55 mm
Physical Dimensions of Ranging unit195.6 mm x 95.1 mm x 56.9 mm
IP Rating – HVB+ VMUIP 66
IP Rating – HVB+ Ranging unitIP 66
Data Logging on DeviceInteraction related events
GSM ReportsSim card activation

Compliance & Certification

ICASA

ISERT

EN IEC 62368-1:2020

IEC 62368-1:2018